We manufacture LED office ceiling lights: panels for modular ceilings, downlights and luminaires for staff rooms. The luminaires have low glare (UGR below 19) and meet the requirements of EN 12464-1 for computer work.
All our smart LED luminaires are made at our plant in Rzeszów.
Our LED luminaires are ready for integration with modern building automation systems: DALI, BT, LoRa, 0–10V.
Innovative solutions without a conventional driver ensure higher reliability and a longer service life.
We help you choose the best lighting solutions for your facility.
We design lighting in line with the standards, improving safety and ergonomics at work.
An investment in our LED luminaires pays for itself quickly thanks to lower operating costs.
| Room | Luminaire | What to look out for |
|---|---|---|
| Open space, offices | PANEL LED SQR, SQR L (up to 170 lm/W, UGR<19) | no glare on monitors, even light on desks |
| Corridors, receptions, conference rooms | DOWNLIGHT | ceiling aesthetics, dimming option |
| Bathrooms, kitchens, staff rooms | PLAFON LED (IP66, IK10, 100 lm/W), DOWNLIGHT | moisture resistance |
| Training rooms, classrooms | HERMES BOARD (CRI>90, asymmetric light distribution) | board lighting without reflections |
The panel fits into the suspended ceiling grid in place of the old fluorescent luminaire. It is the fastest way to replace office lighting without construction work.
A round luminaire recessed into the ceiling, used in corridors, receptions, conference rooms and bathrooms.
| Parameter | Requirement for office and computer work | What it means |
|---|---|---|
| Illuminance | 500 lx at the workstation | bright enough for reading and writing |
| UGR | ≤ 19 | no glare or reflections on screens |
| Ra (CRI) | ≥ 80 | natural colours, less eye strain |
For projects outside Poland, we design according to the regulations of the country where the investment is located.
An office is empty for most of the day and night, and near the windows daylight is sufficient for part of the day. LEDOLUX luminaires work with DALI, 0–10 V, Bluetooth and LoRa, so presence and daylight sensors can be added. The light switches off in empty rooms and dims near the windows.
Replacing fluorescent luminaires with LED panels reduces energy consumption by up to 50%. Following the EU ban on the sale of fluorescent lamps, they will have to be replaced anyway. We will prepare a free design and a calculation of the savings.
At an office workstation, EN 12464-1 requires 500 lx. Corridors and auxiliary rooms require less.
A panel for offices and open-plan spaces with a modular ceiling, a downlight for corridors, receptions and conference rooms.
UGR describes glare. A value of up to 19 means that the luminaire does not dazzle and is not reflected in the monitor.
Yes, the panel fits into the same suspended ceiling grid cell.
Most often neutral, 4000 K.